Ɨ

ECTS2 Series

Harmonics & Flicker Test System, up to 75A

The ECTS2 Test System is designed for advanced harmonics and flicker measurement, featuring updated flicker impedance options to support accurate and reliable testing. It enables compliance with IEC 61000 3 XX standards for harmonics and flicker, as well as IEC 61000 4 XX standards for immunity testing, with capability up to 75A per phase.

The system is available in configurations for both single phase and three phase equipment under test, covering power ranges from 750VA to 100kVA. For grid tied devices, the AZX based ECTS2 Z models are recommended to ensure optimal performance.

All systems operate using a common IEC software platform, providing a consistent and efficient environment for both emissions and immunity testing.

Power:

800VA to 110kVA+

Voltage:

0 up to 440Vac
L-N/762Vac L-L or ±650Vd

Frequency:

15Hz-1000Hz

Why Choose ECTS2 Series

rings [#f0f0f0]Created with Sketch.

All-in-1 Test System

Includes harmonics and flicker and/or immunity system coupled with ac power source

Pass/Fail Automation

Simplified testing saves time and increases productivity

Easy Reporting Built-In

Get results during testing for maximum efficiency

Pre-Compliance Testing to IEC-61000-3 and -4

Provides accurate pre-compliance testing, ideal for test houses

Key Specifications

  • AC only or AC and DC Test Systems
  • Single-Phase and Three-Phase Output Modes
  • Regenerative Systems Available (AZX-based)
  • Programmable Frequency
  • Current and Power Limit Protection
  • EMC Test Software for Harmonics, flicker, and Immunity
  • Detailed test reports to documents EUT compliance
  • Wide Range of Power Levels Available
  • Lumped Flicker Impedance for Flicker Testing
  • Up to 0-600Vac L-N / 1000V L-L Output Voltage available
  • Up to ±425Vdc output on AFX and ±650Vdc output on AZX systems
  • 15-1200Hz (AFX) or 15-1000Hz (AZX) Full Power Bandwidth
  • USB, LAN, GPIB & RS232 Interfaces
  • Transfer Switch Option for IEC 61000-4-11 and -4-34
  • Choice of Cabinet Size

Test to EMC Compliance Standards IEC 61000-3 and -4

Pre-compliance

  • IEC 61000-4-34 AC Voltage Dips, Interruptions and Variations to 75A/phase
  • IEC 61000-4-27 AC Voltage Unbalance three phase
  • IEC 61000-4-28 Frequency Variations

Accurately Simulate Harmonics and Flicker to Test to IEC Standards

The ECTS2 Series of EMC Compliance Test System allows EMC labs to perform full compliance testing of products to the following IEC standards:

Emissions IEC Test Standards Harmonics and Flicker)

  • IEC 61000-3-2 Harmonics and Inter Harmonics to 16A/phase
  • IEC 61000-3-12 Harmonics and Inter Harmonics to 75A/phase
  • IEC 61000-3-3 Flicker to 16A/phase
  • IEC 61000-3-11 Flicker to 75A/phase

Immunity IEC Test Standards

  • IEC 61000-4-11 AC Voltage Dips, Interruptions and Variations to 16A/phase
  • IEC 61000-4-13 Interharmonics
  • IEC 61000-4-14 AC Voltage Fluctuations
  • IEC 61000-4-17 DC Ripple
  • IEC 61000-4-29 DC Voltage Dips, Interruptions and Variations

The ECTS2 systems provide a comprehensive and cost-effective solution for all of your EMC compliance testing needs!

Featured Webinar

EMC Compliance Testing On-Demand Webinar

Single Phase LMX Series AC Source Based ECTS2 EMC Test Systems

Model Rated Power (VA) Output Form Output Volts-Max
(VRMS)
Output Amps
(Arms)
Input Power Form Cabinet Height (U) CTA
Single Phase Systems
ECTS2-108M-x 750 -n1Ƙ 135/270 6/3 1Ƙ n/a Buy / Rent
ECTS2-140M-x 4000 1Ƙ 135/270 32/16 3Ƙ 18 Buy / Rent
ECTS2-160M-x 6000 1Ƙ 135/270 48/16 3Ƙ 18 Buy / Rent

Configuration Options (x):Ā None includes Harmonics, Flicker & Immunity Tests; -B = Harmonics & Flicker Test only; -C = Adds IEC61000-4-13 Interharmonics

Three Phase AFX Series AC &DC Source Based ECTS2 EMC Test Systems

Model Rated Power (VA) Output Form Output Volts-Max
(Vrms LN)
Output Current
@ 230Vac
Input Power Form Cabinet Height (U) CTA
Three Phase Systems
ECTS2-360F-x 6,000 1Ƙ 333 Vrms LN 25 Arms 3Ƙ 18U Buy / Rent
ECTS2-3120F-x 12,000 3Ƙ 333 Vrms LN 17.4 Arms 3Ƙ 18U Buy / Rent
ECTS2-3150F-x 15,000 3Ƙ 333 Vrms LN 21.7 Arms 3Ƙ 18U Buy / Rent
ECTS2-3240F-x 24,000 3Ƙ 333 Vrms LN 38.4 Arms 3Ƙ 18U Buy / Rent
ECTS2-3300F-x 30,000 3Ƙ 333 Vrms LN 43.3 Arms 3Ƙ 18U Buy / Rent
ECTS2-3450F-x 45,000 3Ƙ 333 Vrms LN 65.0 Arms 3Ƙ 28U Buy / Rent
ECTS2-3600F-x 60,000 3Ƙ 333 Vrms LN 87.0 Arms 3Ƙ 28U Buy / Rent
ECTS2-3750F-x 75,000 3Ƙ 333 Vrms LN 108 Arms 3Ƙ 36U Buy / Rent
ECTS2-3900F-x 90,000 3Ƙ 333 Vrms LN 130 Arms 3Ƙ 36U Buy / Rent

Configuration Options (x):Ā None includes Harmonics, Flicker & Immunity Tests; -B = Harmonics & Flicker Test only; -C = Adds IEC61000-4-13 Interharmonics

Three Phase Regenerative AZX Series AC &DC Source Based ECTS2 EMC Test Systems

Model Rated Power (VA) Output Form Output Volts-Max (Vrms LN) Output Current @ 230Vac Input Power Form Cabinet Height (U) CTA
Three Phase Systems
ECTS2-3300Z-
x
30,000 3Ƙ 440 Vrms LN 45.0 Arms 3Ƙ AZX + 28U Buy / Rent
ECTS2-3550Z-
x
55,000 3Ƙ 440 Vrms LN 75.0 Arms 3Ƙ AZX + 28U Buy / Rent
ECTS2-31100Z-
x
110,000 3Ƙ 440 Vrms LN 150 Arms 3Ƙ 2 Ɨ AZX + 28U Buy / Rent

Configuration Options (x):Ā None includes Harmonics, Flicker & Immunity Tests; -B = Harmonics & Flicker Test only; -C = Adds IEC61000-4-13 Interharmonics

NOTES

  • Included Hardware: AC Power Source, Measurement System, Lumped Flicker Impedance, Receptacle Panel, System Wiring, and Power Input Terminals. Cabinet height may vary with additional hardware options like EPTS.
  • Included Software: Harmonics & Flicker (HFA) Software for IEC 61000-3-2 Harmonics and IEC 61000-3-3 Flicker Testing or Harmonics & Flicker (HFA75) Software for IEC 61000-3-12 Harmonics and IEC 61000-3-11 Flicker Testing -B configurations. Software for IEC 61000-4 AC & DC immunity testing on standard configuration. Software for IEC61000-4-13 interharmonics on -C configurations.

Voltage Dips and Interruptions Electronic Power Transfer Switch Options
Click here for information on Electronic Power Transfer Switches forĀ voltage dip compliance tests.

Recommended Options: -413

  • Adds the IEC 61000-4-13 Harmonics and Interharmonics Immunity Test.
  • Includes an interharmonic generator internal to the AC power source and IEC 61000-4-13 test sequences.

Three Phase Regenerative AZX Series AC &DC Source Based ECTS2 EMC Test Systems

Model Rated Power (VA) Output Form Output Volts-Max (Vrms LN) Output Current @ 230Vac Input Power Form Cabinet Height (U) CTA
Three Phase Systems
ECTS2-3300Z-
x
30,000 3Ƙ 440 Vrms LN 45.0 Arms 3Ƙ AZX + 28U Buy / Rent
ECTS2-3500Z-
x
50,000 3Ƙ 440 Vrms LN 75.0 Arms 3Ƙ AZX + 28U Buy / Rent
ECTS2-3600Z-
x
60,000 3Ƙ 440 Vrms LN 90.0 Arms 3Ƙ 2 Ɨ AZX + 28U Buy / Rent
ECTS2-31000Z-
x
100,000 3Ƙ 440 Vrms LN 150 Arms 3Ƙ 2 Ɨ AZX + 28U Buy / Rent