Gustav Klein

I-TS-3870 - DC Source / Sink

The I-TS-3870 from Gustav Klein is a single channel infeed test system designed for the testing and emulation of batteries, fuel cells, and powertrains.

It features one high performance output capable of delivering up to 1200V and 1200A, making it suitable for demanding applications. The system provides a maximum power output of 650kW in single operation, which can be extended up to 1.3MW when operated in parallel, offering flexibility for larger scale testing requirements.

Power:

Up to 756kVA+

Voltage:

350Vac L-N/606Vac
L-L or ±500Vdc

Frequency:

Up to 1,200Hz

Features and Equipment

General Characteristics

  • High-dynamic converter
  • Short-circuit proof lcw < 3 kA or 8 kA (< 8 kA for 1000 A systems)
  • Control accuracy 0.1% fs
  • Residual ripple voltage and current < 0.1% fs
  • Measurement accuracy voltage and current 0.1% fs
  • Connection terminals for sense line for DC voltage measurement
  • Current rise time < 1 ms (up to 800 V), < 1.3 ms (1000 V)
  • Seamless transition source/sink
  • TFT display with touch operation
  • Protection class IP20
  • Air-cooled
  • High efficiency 

Safety Equipment

  • Safety controller for performance level d (PLd) according to ISO 13849-1 / EN 60204-1
  • DC output contactor
  • Galvanic isolation for mains supply
  • Main switch (load break switch with fuses in the AC input; lockable in the off position)
  • Stop switch (black mushroom button) in control cabinet door
  • Voltmeter and green indicator light in the cabinet door
  • Connection terminals for external emergency stop
  • Connection terminals for external stop

Interfaces (some optional)

  • Modbus TCP/IP
  • CAN bus
  • VNC over Ethernet
  • SCPI
  • EtherCAT
  • PROFIBUS
  • PROFINET
  • Analog interface
  • LabVIEW driver package
  • Matlab-Simulink (Running Matlab-Simulink projects)
  • Additional interfaces are available as an option.

Options (excerpt)

  • Insulation monitoring
  • Protection diode (no source operation)
  • Parallel run
  • Control cabinet for installing various equipment options (e.g. test bench switching, discharge unit, etc.)
  • Discharge Unit
  • PDU (connection box for test subject)
  • Performance level “e”
  • Emergency stop in cabinet door
  • Adjustment of the protection rating of control cabinets (IP21 – IP54)
  • Water cooling instead of air cooling

Typical Applications

  • Battery tests (charging and discharging tests of batteries)
  • Battery simulation / battery emulation
  • Load for fuel cells
  • Test power supply for component testing (e.g. contactors, cables, circuit breakers…)
  • Testing of DC motors (drive train)
  • EV / EVSE Testing of charging stations
  • Power supply to trains for maintenance purposes in the ICE workshops

Technical Data

TYPE I-TS-3870 & MI-TS-3871

Specification Details
Input Voltage / Input Frequency 380 / 400* / 440 / 480 / 500 / 690 V ±10%
3-phase, PE
50 / 60 Hz ±5%
Measurement Resolution Voltage: 16-bit ADC
Current: 16-bit ADC
Control Accuracy Voltage: 0.1% fs
Current: 0.1% fs
Voltage Ripple ≤ 0.1% effective fs
Current Ripple ≤ 0.1% effective fs
Dynamic Voltage Tolerance
(0–100% nominal in 3 ms)
Battery tester < 3%
Battery simulator < 1%
Short-Circuit Behavior Systems up to 600A: Icw < 3 kA
Systems > 600A: Icw < 8 kA
Minimum Distance from Ceiling 300 mm (Standard, IP20)
Permissible Environmental Conditions Storage: EN 60721-3-1
Transport: EN 60721-3-2
Operation: EN 60721-3-3

1K21 / 1M11, +5 to +40 °C
2K12 / 2M4, -45 to +70 °C
3K22 / 3M11, +5 to +40 °C
Lineup Workplace with restricted access;
Installation on non-combustible flooring
Protection Class IP20 according to IEC 60529
(others available on request)
Security EN ISO 13849-1
Basic Standard EN 62040
EMC EN 61000-2-4 (Mains disturbances)
EN 61000-6-2 (Immunity)
EN 61000-6-4 (Emission)
EN 61800-3 Cat C2 (A1) (Variable speed drives)

*Standard 400 V